• Sensor measuring range: −55 to + 127.0 °C
• Operation and monitoring free functioning
• Adjustable to heating or cooling
• Temperature adjustment in steps of 0.1 °C
• Remote measurement of up to 50 m
After the temperature switch has detected the current ambient temperature, it automatically switches the connected consumer on and off again as soon as the desired temperature is reached. For example, with a connected fan heater, the thermal switch can react as soon as the room temperature falls below 20°. It activates the fan heater and this heats until the set target temperature is reached. Afterwards the device switches itself off again automatically.
This practical function can be used wherever the room temperature needs to be kept under control. This includes a greenhouse in winter, a hobby room in the basement, a turtle terrarium, an electric outdoor sauna and many other possibilities. The switch can be used in many different ways and can also be used as a frost monitor, as a replacement for defective mechanical thermostats or digital thermometers.
Note: The connected device must not exceed 2300 VA.
Properties:
– Accuracy:
in the range −55 °C to −10 °C: ±2 °C
in the range −10 °C to +85 °C: ±0.5 °C
in the range + 85 °C to +127 °C: ±2 °C
– Unit ambient temperature: −10 to +40 °C
– Silicone cable Temperature range: −55 to +200 °C
– Display can be rotated by 180° using keys
– Temperature sensor type: Maxim DS 18B20 (with 2-m cable supplied)
– Min./ max. display
– Hysteresis (switching accuracy) freely adjustable (0.1 °C to 10 °C )
– Remote measurement up to 50 m
– Sensor monitoring for short circuit & interruption
– Output switches off in case of sensor error
– Operation and monitoring free functioning
– Adjustable to heating or cooling
– OLED display for temperature setting, relay (socket) on, sensor error, heating, cooling
– Storage of the programmed switching thresholds even in case of power failure
– Automatic restart after power failure
Abmessungen: | 60 x 40 x 98 mm |
---|---|
Farbe: | rot, weiß |
Kabellänge (m): | 2 Meter |
Leistungsaufnahme: | 0,3 VA (Stand-by) |
Material: | Kunststoff |
Max. Eingangsleistung (W): | 1840 Watt |
Max. temperature: | 127 °C |
Maximaler Betriebsstrom: | 10 Ampere |
Min. temperature: | -55 °C |
Netzspannung/Frequenz (V~Hz): | 220–240 V / 50 Hz |
Produktart: | Temperaturregler |
Schutzart (IP): | IP20 |
präzise Produktart: | Temperaturschalter |
Empfehlung: Schalter Temperatur
Aktualnie niedostępne
• Reduces the switch-on load peaks
• For angle grinders, circular saws, compressors, pumps, drills, etc.
• Max. 16 A nominal voltage, max. 3680 W nominal power
• Suitable for circuits with 16 A fuse protection
Aktualnie niedostępne
• Operation and monitoring free functioning
• Adjustable to heating or cooling
• Temperature adjustment in steps of 0.1 °C
• Remote measurement of up to 50 m
Empfehlung: Wasserstand Schalter-Regler
Aktualnie niedostępne
• max. working temperature 50°C
• Switching angle +/- 50°
• Cable length: 10 m
Aktualnie niedostępne
• max. working temperature 50°C
• Switching angle +/- 50°
• Cable length: 10 m
Aktualnie niedostępne
• max. working temperature 50°C
• Switching angle +/- 50°
• Cable length: 2 m
Aktualnie niedostępne
• max. working temperature 50°C
• Switching angle +/- 50°
• Cable length: 2 m
Aktualnie niedostępne
• max. working temperature 50°C
• Switching angle +/- 50°
• Cable length: 5 m
Aktualnie niedostępne
• max. working temperature 50°C
• Switching angle +/- 50°
• Cable length: 5 m
Aktualnie niedostępne
• max. working temperature 50°C
• Switching angle +/- 50°
• Cable length: 5 m
Aktualnie niedostępne
• HDPE ball Ø155mm, welded stainless-steel loop
• Footvalve Ø48mm 1" external thread with filter 1 mm mesh size
• Threaded spout 1" external thread and W4 clamp for 1" hose
• Entirely pre-assembled for connecting to a pump hose
Aktualnie niedostępne
• Składanie osłon przeciwsłonecznych lub markizy
• Zamykanie okien dachowych
• Z funkcją ogrzewania przeciwdziałającego oblodzeniu/osadom rosy
• Możliwość montażu na dachu płaskim, pochyłym lub na ścianie domu
Aktualnie niedostępne
• To detect leakage & flooding at an early stage
• Sounds alarm in case of water contact (82 dB)
• Moisture sensor to prevent consequential damage
• Alerts to pipe burst, flooding, heavy rain, etc.
Aktualnie niedostępne
• Sensor cable 10 m
• 160 x 80 x 60 mm
• Cable length 2 m
Aktualnie niedostępne
• Responsivity for reaction < 50 kOhm
• Sensor Cable 10 m
• Range of function: –15 °C / +40 °C
• LED display for: Level, mains, Rel. Ein
• Cable Length: 2 m
Aktualnie niedostępne
• Czułość wyzwalania < 50 kiloom
• Długość kabla 2 m
• Zakres temperatury roboczej: −15 °C / +40 °C
• Wyświetlanie: Min/Maks. czujnika, sieć, błąd, Rel. wejście
• Długość przewodu czujnika: 2x 10 m
Aktualnie niedostępne
• Trigger sensitivity 10/200 kOhm
• Sensor cable 30 m
• Functional area –15 °C / +40 °C
• Cable length 2 m
Aktualnie niedostępne
• Cable length 10 m
• For water level switch
Aktualnie niedostępne
• Cable length 10 m
• Suitable for water level switch
• WPS 3000 & WPS 3000plus
Aktualnie niedostępne
• Cable length 30 m
• Suitable for the water level switch
• WPS 5000
Aktualnie niedostępne
• max. working temperature 50°C
• Switching angle +/- 50°
• Cable length: 10 m
Aktualnie niedostępne
• max. working temperature 50°C
• Switching angle +/- 50°
• Cable length: 2 m
Aktualnie niedostępne
• Praktyczne zabezpieczenie przed przelewem dla stawów
• Wyłącza się przy za wysokim poziomie wody
• Zapewnia bezpieczeństwo w nieobserwowanych momentach
• Kabel o długości 5 m
Aktualnie niedostępne
• Useful dry-out protection for ponds
• Switches pump off with too low a water level
• Provides safety for unattended moments
• 5 m long cable